Designed to improve intraoperative specimen margin assessment to help achieve better surgical outcomes, VisionCT is the first FDA approved micro-CT providing true three-dimensional specimen radiography for excised specimens.
VisionCT FEATURES
Fast and Versatile
Automatically obtain traditional 2D orthogonal images in under 30 seconds and scan and reconstruct the whole specimen volume (up to 512 frames) in under 4 minutes with GPU-accelerated Real Time Reconstruction.
Turn-Key and Fully Automated
VisionCT requires no manual specimen repositioning. Automatic magnification allows for optimal resolution based on the specimen size. Review orthogonal images while the specimen is being scanned and reconstructed. Automatic metal artifact correction minimizes interference from metal clips and markers.
Greatest Margin Assessment
Go beyond tomosynthesis for significantly improved margin assessment. VisionCT provides true 3D specimen radiography.
High-Resolution
The micro focus tube and up to 4X automatic geometric magnification provide 2D and 3D spatial resolution down to 25um (20 lp/mm).
Easy to Use
No additional x-ray shielding or specialized knowledge required to operate VisionCT. Simply place specimen in disposable holder, insert container in chamber and start scan with one button.
Compact Footprint
Featuring a compact design, VisionCT was created to minimize intrusion in the OR.
PACS Compatible
DICOM images are automatically stored to PACS and saved to a local or network drive. The images are instantaneously displayed on an included 24” high-resolution 3.7MP monitor.
All Top 10 US Cancer Centers Use Faxitron Solutions
University of Texas MD Anderson Cancer Center - Houston, TX
Memorial Sloan Kettering Cancer Center - New York, NY
Mayo Clinic - Rochester, MN
Dana-Farber/Brigham and Women’s Cancer Center - Boston, MA
UCLA Medical Center - Los Angeles, CA
Moffitt Cancer Center and Research Institute - Tampa, FL
Seattle Cancer Care Alliance/ University of Washington Medical Center - Seattle, WA
Cleveland Clinic - Cleveland, OH
Johns Hopkins Hospital - Baltimore, MD
UCSF Medical Center - San Francisco, CA
Specifications
Specimen Imaging Area: 2.4MP CMOS with CsI Scintillator
Voxel resolution: Down to 25um at 10% MTF at 4X Magnification
Energy Range: 50kV
Tube current: 0.24mA
Focal spot size: Less than 15um
Window filtration: 0.25mm Be, tungsten source
Power: 100-240VAC ±10%, 50/60Hz, 200VA
DICOM Interface: Store, Annotate, and Modality Worklist
External dimensions: 178cm H x 72cm W x 70 cm D (70” x 28.5” x 27.5”)
Chamber dimensions: 19cm H x 30cm W x 19cm D (8” x 12” x 8”)
Weight: 170lbs (77kg)